Specification:

Performance of Scope
B   Bandwidth (-3dB) 50MHz
Sampling Rate Max. real time sampling rate 200MSa/s
Channel 1

Coupling

AC, DC
Rise Time ≤ 7.6ns
Input Impedance 1MΩ, ≤ 20pF
Max Input Voltage 1x CAT III 300 VAC 10x, 100x CAT III 600 VAC
Vertical Resolution 8 bit
Vertical Sensitivity 10mV/div – 5V/div
Horizontal Resolution 2ns/div
Horizontal Sensitivity 2ns – 5s
Record Length 4K/channel
Memory 6 memory locations
Trigger Mode Auto, Normal, Single
Trigger Type Edge trigger
Basic Performance    
Screen 320×240 pixels (RGB), with LED backlight
Communication USB, PC software
Battery 3.7V lithium polymer battery, 4Ah
Operating Environment    Temperature:   0℃ – 40℃
 Humidity:   ≤ 75%
Storage Environment Temperature:   -10℃ – 50℃
Humidity:   ≤ 85%
Operating Altitude    0 – 2000m
Size 218mm × 118mm × 50mm ( including holster )
Weight 700g(main body only)
Performance of multimeter
Display 6000 counts
Input Max. Input Voltage: 600 Vrms CAT II, 300 Vrms CAT III
Continuity Test Beeps at < 25Ω, in 600Ω range
Diode Test If the voltage drop of the diode under test is more than 2V
or if the test circuit is open, the display will show ” OL “.  If the
voltage drop is less than 0.25V, the built-in buzzer will sound.
Capacitance Measurement 6.000nF – 6mF
Resistance Measurement 600.0Ω – 60.00MΩ
Voltage Measurement 6.000V – 600V
Waveform output performance
Amplitude Output amplitude is adjustable.

Output amplitude range:   0 – 2.5V

Output amplitude accuracy:  ± 2% for amplitudes < 2V

± 5% for amplitudes > 2V

Frequency There is no frequency setup for dc output.

Output frequency range:  26Hz – 50kHz

Output frequency accuracy: ± 2%

Specification of Scope
Vertical System:  channel of Scope
Bandwidth (-3dB) 50MHz
Accuracy 10mV/div to 20 mV/div:  ± 5% full scale
50mV/div to 5V/div:  ± 3% full scale
Vertical Offset Accuracy (DC) ±0.2 div ±2mV ±0.5% offset value
Trigger Sensitivity DC to 50 MHz: 0.8 div
Horizontal System:  time base of Scope
Horizontal Sensitivity 2ns/div – 5s/div, in 1-2-5 step
Horizontal Accuracy < ( 0.01% + 1 pixel )
Specification of probe
Rise Time X1    < 23.3ns
X10   < 7.6ns
Bandwidth X1    DC – 8MHz
X10    DC – 50MHz
Input Impedance X10   10MΩ (not including the Scope’s input resistance 1MΩ)
Input Capacitance X1   46pF ( not including the Scope’s input capacitance )
X10   about 15pF
Specification of Multimeter         
Function Range Frequency, test current, or load

voltage

Condition: at calibration temperature±5℃, for 1

year

Voltage
DC Voltage 6.000V 1.0 + 8
60.00V 0.5 + 8
600.0V 0.5 + 8
AC Voltage 6.000V – 600.0V 40Hz – 400Hz 1.0 + 10
400Hz – 2kHz 5.0 + 10
Resistance

600.0Ω

1.0 + 5
6.000kΩ 1.0 + 5
60.00kΩ 1.0 + 5
600.0kΩ 1.0 + 5
6.000MΩ 1.0 + 5
60.00MΩ 2.0 + 10
Capacitance
6.000nF 3.0 + 8
60.00nF 3.0 + 8
600.0nF 3.0 + 8
6.000μF 3.0 + 8
60.00μF 3.0 + 8
600.0μF 3.0 + 8
6.000mF 3.0 + 8
Continuity Buzzer beeps if the resistance is less then about 25Ω.
Diode Buzzer beeps if the forward voltage drop of the diode is < 0.25V.